PRODUCTS

Trip relay, monostables and latching

Trip relays, with reduced switching times (e.g. <10ms) compared to standard relays (e.g. < 20ms).

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
RGR

2

5

DC Fast-acting < 2,5ms, reed tecnology
RGMV16X

4

10

DC or AC Fast-acting (trip relay) <8ms, monostable
RGMV17X

4

10

DC Fast-acting (trip relay) <8ms, monostable, High-Burden (HB)
RMMV12X

8

10

DC or AC Fast-acting (trip relay) <8ms, monostable
RMMV16X

8

10

DC Fast-acting (trip relay) <8ms, monostable, High-Burden (HB)
RMMV11

12

10

DC or AC Fast-acting (trip relay) <10ms, monostable
RMMV17

12

10

DC Fast-acting (trip relay) <10ms, monostable, High-Burden (HB)
RV LV16

6

5

DC Ultra Fast-acting (trip relay) < 6ms, monostable
RGMV

4

10

DC Fast-acting (trip relay) < 8ms, monostable
RMMV

8

10

DC Ultra Fast-acting (trip relay) < 6ms, monostable
RMMZ11

8

10

DC Fast-acting (trip relay) < 8ms, monostable
RGBV14x

4

10

DC or AC Fast-acting (trip relay) <10ms, latching
RGBV16X

4

10

DC Fast-acting (trip relay) <10ms, latching, High-Burden (HB)
RMBV12X

8

10

DC or AC Fast-acting (trip relay) <10ms, latching
RMBV14X

8

10

DC Fast-acting (trip relay) <10ms, latching, High-Burden (HB)
RMBV15

12

10

DC or AC Fast-acting (trip relay) <10ms, latching
RMBV16

12

10

DC Fast-acting (trip relay) <10ms, latching, High-Burden (HB)

Forcibly guided contacts

The contacts are mechanically linked. These relays use special features to ensure the make contacts (normally open) cannot assume the same state as the break contacts (normally-closed).

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
RCG

2

10

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3 type A
RDG

4

10

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3 type A
RGG

4

12

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RGK

4

12

DC or AC Timed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RMGX

8

10

DC or AC Forcibly guided contacts, weld-no-transfer, EN61810-3, type A, high breaking capacity
RMGW

8

10

DC or AC Forcibly guided contacts, weld-no-transfer, NF F62-002 (§12.3.10)

Latching

Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
OKBA

4

10

DC or AC 8 C/O as option
BAS8

8

10

DC or AC
RGB

4

12

DC or AC
RMBX

8

10

DC or AC Multi-contacts
RMB

8

12

20

10

DC or AC Multi-contacts

Instantaneous, monostable

The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
POK

2

5

DC or AC Compact, magnetic arc blow-out
POKS

2

10

DC or AC Compact, magnetic arc blow-out
BIPOK

4

5

DC or AC Compact, magnetic arc blow-out
BIPOKS

4

10

DC or AC Compact, magnetic arc blow-out
TRIPOK

6

5

DC or AC Compact, magnetic arc blow-out
TRIPOKS

6

10

DC or AC Compact, magnetic arc blow-out
QUADRIPOK

8

10

DC or AC Compact, magnetic arc blow-out
ESAPOK

12

10

DC or AC Compact, magnetic arc blow-out
OK

4

8

12

10

DC or AC 8 and 12 C/O as option, available in Italian Navy version, 100.000.000 operatioons
OKS

4

8

12

10

DC or AC 8 and 12 C/O as option, 100.000.000 operations, magnetic arc blow-out
OKFC

4

8

12

10

DC or AC 8 and 12 C/O as option, 100.000.000 operations, low consumption
OKSFC

4

8

12

10

DC or AC 8 and 12 C/O as option, 100.000.000 operations
OKUIC

4

10

DC or AC TRENITALIA approved, 100.000.000 operations
OKSCD

4

10

DC or AC Very high breaking capacity, 100.000.000 operations
OKSGcCd

4

10

DC or AC Very high breaking capacity, contact gap 4mm, 100.000.000 operations
OKB184

4

10

DC K3 compliant
FOKB

4

13

DC Double break, NF-F 62002 compliant
RCM

2

10

DC or AC Compact
RDM

4

10

DC or AC Compact
RGM

4

12

DC or AC Very high breaking cap.
RMMX

8

10

DC or AC Multi-contacts
RMM

8

12

20

10

DC or AC Multi-contacts

Time delayed, pick-up, drop-out, logic

The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
TMM2

4

10

DC or AC Multifunction relay, 10 functions, 2 timed + 2 inst. contacts
TMM4

4

10

DC or AC Multifunction relay, 10 functions, 4 timed contacts
TM2E TMS2E

4

5

10

DC or AC Wide scale, Delay ON (2) + INST (2)
TM4E TMS4E

4

5

10

DC or AC Wide scale, Delay ON
TM2R TMS2R

4

5

10

DC or AC Wide scale, Delay OFF (2) + INST (2)
TM4R TMS4R

4

5

10

DC or AC Wide scale, Delay OFF
TOKE

4

10

DC or AC Delay ON, 100.000.000 operations
TOKR

4

10

DC or AC Delay OFF, 100.000.000 operations
OKTF

4

10

DC or AC Delay OFF, no power supply
OKTA

4

5

DC or AC Delay ON
OKTR

4

5

DC or AC Delay OFF
OKRE

4

5

DC or AC Delay ON
OKRR

4

5

DC or AC Delay OFF
UTME DC Static time delay unit, delay ON
UTMR DC Static time delay unit, delay OFF
TOK-L

4

5

DC or AC Flashers, 100.000.000 operations
OKRE-L

4

5

DC or AC Flashers
TOK-FP

4

5

DC or AC One-shot, 100.000.000 operations
OKRE-FP

4

5

DC or AC One-shot
CLE

4

5

DC or AC Flashers, fixed time
RGK

4

12

DC or AC Timed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RDT

4

10

DC or AC Delai ON or delai OFF
RDL

2

10

DC or AC Flashers
RGL

2

12

DC or AC Flashers
RDTE15

4

10

DC Delai OFF, no power supply
RDTE16

4

10

DC or AC Delai OFF, no power supply
RGTO

2

12

DC or AC Delai OFF, no power supply
RMTZ04

4

10

DC RFI (Italian Railway) approved, T2 type relay
RMTZ05

4

10

DC RFI (Italian Railway) approved, T1 type relay
RMTZ07

4

10

DC RFI (Italian Railway) approved, T3 type relay

Measurement

The contacts change status for a defined input power value.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
MOK-V2

2

5

DC or AC Measuring relay, voltage threshold
OKPH

2

5

AC Sequence & detection phase
MOK-PH2

2

5

AC Sequence & detection phase
TD

4

10

DC or AC Current monitoring
MAMF12

2

10

DC Insulation between input and contact: 12kV
MAVF1X

2

10

DC Measuring relay, insulation 15kV

Coil continuity check

Monostable or bistable relays, coil continuity supervision and monitoring by means of a built-in auxiliary relay.

Model Contacts Nominal
Current
Coil input Heavy duty use Rolling Stock Note
RMN

4

8

16

10

DC or AC Monostable, coil continuity check
RMD

4

8

16

10

DC or AC Latching, coil continuity check
Choose your Relay close
SEARCH BY TYPE
SEARCH BY APPLICATION
SEARCH BY MODEL
SEARCH BY NAME