AMRA-MTI LINE

Trip relay, monostables and latching

Trip relays, with reduced switching times (e.g. <10ms) compared to standard relays (e.g. < 20ms).

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
RGR

2

5

DCFast-acting < 2,5ms, reed tecnology
RGMV16X

4

10

DC or ACFast-acting (trip relay) <8ms, monostable
RGMV17X

4

10

DCFast-acting (trip relay) <8ms, monostable, High-Burden (HB)
RMMV12X

8

10

DC or ACFast-acting (trip relay) <8ms, monostable
RMMV16X

8

10

DCFast-acting (trip relay) <8ms, monostable, High-Burden (HB)
RMMV11

12

10

DC or ACFast-acting (trip relay) <10ms, monostable
RMMV17

12

10

DCFast-acting (trip relay) <10ms, monostable, High-Burden (HB)
RGMV

4

10

DCFast-acting (trip relay) < 8ms, monostable
RMMV

8

10

DCUltra Fast-acting (trip relay) < 6ms, monostable
RMMZ11

8

10

DCFast-acting (trip relay) < 8ms, monostable
RGBV14x

4

10

DC or ACFast-acting (trip relay) <10ms, latching
RGBV16X

4

10

DCFast-acting (trip relay) <10ms, latching, High-Burden (HB)
RMBV12X

8

10

DC or ACFast-acting (trip relay) <10ms, latching
RMBV14X

8

10

DCFast-acting (trip relay) <10ms, latching, High-Burden (HB)
RMBV15

12

10

DC or ACFast-acting (trip relay) <10ms, latching
RMBV16

12

10

DCFast-acting (trip relay) <10ms, latching, High-Burden (HB)

Forcibly guided contacts

The contacts are mechanically linked. These relays use special features to ensure the make contacts (normally open) cannot assume the same state as the break contacts (normally-closed).

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
RCG

2

10

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3 type A
RDG

4

10

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3 type A
RGG

4

12

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RGK

4

12

DC or ACTimed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RMGX

8

10

DC or ACForcibly guided contacts, weld-no-transfer, EN61810-3, type A, high breaking capacity

Latching

Relay with 2 latched contact positions. The contacts change state with an electrical pulse supplied by one of the 2 power coils. To restore the starting position of the contacts, the other coil must be powered.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
RGB

4

12

DC or AC
RMBX

8

10

DC or ACMulti-contacts
RMB

8

12

20

10

DC or ACMulti-contacts

Instantaneous, monostable

The contacts change position instantaneously when the relay is powered and return instantaneously to their initial position when power is shut off.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
RCM

2

10

DC or ACCompact
RDM

4

10

DC or ACCompact
RGM

4

12

DC or ACVery high breaking cap.
RMMX

8

10

DC or ACMulti-contacts
RMM

8

12

20

10

DC or ACMulti-contacts

Time delayed, pick-up, drop-out, logic

The contacts change status with time delay T with respect to the energization or de-energization of the relay input circuit. Logical function relays can be used for various functions, including CYCLIC, ONE-SHOT, etc.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
RGK

4

12

DC or ACTimed with forcibly guided contacts, weld-no-transfer, EN61810-3 type A, high breaking capacity
RDT

4

10

DC or ACDelai ON or delai OFF
RDL

2

10

DC or ACFlashers
RGL

2

12

DC or ACFlashers
RDTE15

4

10

DCDelai OFF, no power supply
RDTE16

4

10

DC or ACDelai OFF, no power supply
RGTO

2

12

DC or ACDelai OFF, no power supply
RMTZ04

4

10

DCRFI (Italian Railway) approved, T2 type relay
RMTZ05

4

10

DCRFI (Italian Railway) approved, T1 type relay
RMTZ07

4

10

DCRFI (Italian Railway) approved, T3 type relay

Measurement

The contacts change status for a defined input power value.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
TD

4

10

DC or ACCurrent monitoring
MAMF12

2

10

DCInsulation between input and contact: 12kV
MAVF1X

2

10

DCMeasuring relay, insulation 15kV

Coil continuity check

Monostable or bistable relays, coil continuity supervision and monitoring by means of a built-in auxiliary relay.

ModelContactsNominal currentCoil inputHeavy duty useRolling sockNotes
RMN

4

8

16

10

DC or ACMonostable, coil continuity check
RMD

4

8

16

10

DC or ACLatching, coil continuity check